Deprecated: Array and string offset access syntax with curly braces is deprecated in /home/narfoamkarcom/public_html/libraries/joomla/filesystem/path.php on line 143

Deprecated: Array and string offset access syntax with curly braces is deprecated in /home/narfoamkarcom/public_html/libraries/joomla/filesystem/path.php on line 146

Deprecated: Array and string offset access syntax with curly braces is deprecated in /home/narfoamkarcom/public_html/libraries/joomla/filesystem/path.php on line 149

Deprecated: Array and string offset access syntax with curly braces is deprecated in /home/narfoamkarcom/public_html/libraries/joomla/user/helper.php on line 610
FIRElink-400 - Narfoamkar
S5 Corporate Response - шаблон joomla Книги
Fire Alarm System

Deprecated: Array and string offset access syntax with curly braces is deprecated in /home/narfoamkarcom/public_html/libraries/idna_convert/idna_convert.class.php on line 421

Deprecated: Array and string offset access syntax with curly braces is deprecated in /home/narfoamkarcom/public_html/libraries/idna_convert/idna_convert.class.php on line 435

Deprecated: Array and string offset access syntax with curly braces is deprecated in /home/narfoamkarcom/public_html/libraries/idna_convert/idna_convert.class.php on line 826

Deprecated: Array and string offset access syntax with curly braces is deprecated in /home/narfoamkarcom/public_html/libraries/idna_convert/idna_convert.class.php on line 957

Deprecated: Array and string offset access syntax with curly braces is deprecated in /home/narfoamkarcom/public_html/libraries/vendor/joomla/registry/src/Format/Ini.php on line 170

Deprecated: Array and string offset access syntax with curly braces is deprecated in /home/narfoamkarcom/public_html/libraries/vendor/joomla/registry/src/Format/Ini.php on line 187

FIRElink-400

4 Pipe Aspirating Smoke Detector

Model FIRElink-400 is designed to provide very high sensitivity smoke detection using an aspirating technique.  A unique sensing technology ensures that the detector operates at optimum sensitivity for the protected environment, without the need for complex set-up.

The detector is available in three formats, the standard detector (FIRElink-400), the standard detector plus Command Module (FIRElink-400CM) and a standalone Command Module (FIRElink-CM).  The Command Module variants provide a single location display, control and interfacing option for systems of up to 127 detectors and allow global programming of all detector functions simultaneously.

  • Volt-free Fire-1 and Fault relay outputs are provided for remote monitoring by local fire detection or BMS systems
  • High sensitivity provided by laser based forward light scatter for reliable early warning
  • Four sampling pipes up to 200m (aggregate) in length (still air)
  • False alarms reduced by unique laser sensing technology - able to discriminate against dust
  • RS485 communications built in as standard for networking and remote communications

Certificates